What does the 'gap' in Parallelism (high speed rules) mean?
Another question: I am needing to use the high speed rules for the first time, and am learning what it can do. I am confused on the 'Parallelism' rules however. You can enter a length maximum that...
View ArticleNo way to DRC for matched lengths with the high speed tool?
We have the older 'Advanced Rules Set' option which includes the high speed tool options Apparently, there is no way to designate a set of nets into a class and then have them all DRC checked to be...
View ArticleReturn and insertion loss profile of 5'' PCB TRACE
I have generated S-parameters for 5 inch differential trace, there are sharp dips in return and insertion loss profile can anyone tell me the reason there is no discontinuity in the trace width (no...
View ArticleRe: No way to DRC for matched lengths with the high speed tool?
PADS Layout does not natively check Matched Length violations, however, you can use Tools > Verify Design > Latium Design Verification with 'Trace Length' enabled in the Setup dialog. This will...
View ArticleRe: What does the 'gap' in Parallelism (high speed rules) mean?
Gap refers to the minimum distance the two traces must be away from one another when traces are running parallel to each other for more than the parallelism length specified. Be sure one or more of...
View ArticleRe: Do I need to renew my support to keep using my current version?
Thanks for you your help, its getting me closer to finding my answer... How do I determine if the license is a "perpetual license"? ...I checked the license, no where do I find this info or any other...
View ArticleRe: What does the 'gap' in Parallelism (high speed rules) mean?
Thanks Bill, toggling on the 'aggressor' box did cause it to finally see any violations I was creating. And now I understand the 'gap' value, thanks Randy
View ArticleRe: Do I need to renew my support to keep using my current version?
Joe, Generally, if your license expiration date is three months after the end of your support contract, your license is perpetual. But there's nothing explicitly indicating a perpetual license in the...
View ArticleRe: Do I need to renew my support to keep using my current version?
Thanks for this info.
View ArticleRe: Restricting modify access to the VeSys database
Sorry Bob, but I have no idea. That is not an area of expertise for most of the people on this forum, I suspect. You might pose your question in the Vesys Electrical forum. Best regards,Ken...
View ArticleAssembly and Silkscreen Ref Des rearrange
Hi All, we all know that in the end of the layout we need to rearrange Assembly and Silkscreen Ref Des according the component shape, limitations, and orientation.Is there any way to sort the Assembly...
View ArticleRe: Return and insertion loss profile of 5'' PCB TRACE
It seems that lossy simulation was not enabled in hyperlynx (Setup → enable lossy simulation)The sharp dips are related to the trace length (resonance frequency), doesn't see a termination at the end?
View ArticleReference impedance to be used while extracting s parameters of differential...
While extracting s parameters of differential line it asks for reference impedance, i provided 50 ohms for 100 ohm differential traceIf it is a 90 ohm differential trace should i provide 45 ohms or 50...
View ArticleRe: Return and insertion loss profile of 5'' PCB TRACE
While assigning ports there is a reference impedance of 50 ohms, that means it is terminated.
View ArticleREFERENCE IMPEDANCE while extracting s parameters
Below is the topology that i have used for simulation, i have used scattering parameters of 5 inch trace for simulation so while extracting s parameters there is an option of selecting reference...
View ArticleRe: Custom Anti-pads Not Working!
Randy,Hope you found the answer by now but here is another possibility. Anti-pad shape is lost under copper to drill setting. Copper fill is using largest of two.William
View ArticleHow to verify splice criteria based on existing Design Rule Checks?
I created a splice with following settings:The splice is placed in integrator plane. To the splice I connected 4 wires:where 4008A is set intentionally to be 4mm2 (not according to the previously...
View ArticleRe: Assembly and Silkscreen Ref Des rearrange
Hi,yes, thats also currently my problem. But here I have a small macro for you doing exactely that job.It is written in VB.Net, but it is easy to transfer to VBS. It is a cutout of something bigger I...
View ArticleHow get the attached parts of Back shells of connectors, Grommets & other...
Hello,We designed our schematic by Vesys 2.0 and then we export the wire information by NX Wiring integration format (xml) and we did the routing at NX. My question is after we flatten back the NX...
View ArticleInstalling Artistlink with Cadence
Hello, I am trying to install AMS 16.1.1 with Cadence 6.1.6.I followed the documentation in order to install Artist link (in my setup script, I set the MGC_AMS_HOME variable, I copied the setup.loc...
View Article