PASS THE REFDES VALUE FROM DXDATABOOK

Hi, is it possbile to pass the REFDES value to a component in the schematic from the databook? I created different symbol for my RESISTORS table (resistor.1, jmp_resistor.1, etc,..) leaving the REFDES...

View Article


Re: Changing symbol in xDx Databook

Thank you Robert. I am using a Central Library.I was able to edit it in the access database so that all the TANT Capacitors are calling out the symbol with polarity.Thank you for your support. 

View Article


Re: ECO Errors from PADS Logic to PADS Layout

First, I've never used the 'ECO Names' tab in my many years of using Logic; I always use the default with no issues.   Second, placement data doesn't transfer from Logic to Layout during the ECO...

View Article

Re: Job not compatible with current version of program

Hello, I'm currently using PADS VX.1.1 and receiving  the following message of "Job not compatible with current version of program" Any help/comments greatly appreciated. Thanks,Peter

View Article

How to get a list of open netlines

How can I get list of open netlines in Expedition? Thank you

View Article


Re: Job not compatible with current version of program

I also have a file that like that.  I am running 9.5.  I saved a file I was working on last night and 3 hours later when I opened it, it gave me the "job not compatible with current version of the...

View Article

Re: ECO Errors from PADS Logic to PADS Layout

Definitely placement file is generated from Layout through Tools ---> Basic Scripts ---> Basic Scripts with the help of script . But when a component value is changed is schematic or interfaces...

View Article

Re: 3D via modelling in hyperlynx v9.2

Hi,I selected an option of adaptive intelli-fit in 3D solver, because of that it is simulating within 2 minutes, but while deselecting that option it takes about 30 minutes to simulate the entire...

View Article


Re: 3D via modelling in hyperlynx v9.2

That's what AIF was made for - total run time reduction be reducing the number of simulated frequencies and interpolation the frequencies between the simulated frequencies. You may see in the...

View Article


Image may be NSFW.
Clik here to view.

Get Active Part Type in Pads Layout script

I trying to get the substituted part from within a VB script in Pads Layout (the Active column) If I list all parts in an assembly variant it possible to see if a specific part is substituted but how...

View Article

Image may be NSFW.
Clik here to view.

Can´t start PCB Browser

Hello, I want to use the Mentor Expedition PCB Browser (xPCB Browser VX.1.1)After installation I can´t start the Browser, and a windows failure occures:  Does anybody about this problem and can help me...

View Article

Preventing License from being locked when network connection is lost

We have a user who checks out a license for ModelSim. Everything works fine. However, when they lose internet connection and regain it back, the license is still locked. It will not recognize it being...

View Article

Image may be NSFW.
Clik here to view.

Re: batch install failing becasue of spaces in path name

Hello Andrew,     I updated the batch file with the code above but I am still getting the following error. I am working with our IT dept and looking at the possibility of just adding an _ to the...

View Article


HyperLynx signal- and power-integrity simulator has stopped working

Hello All,I'm using Hyperlynx 9.2 and recently I face an issue when selecting a signal, soon after selecting a signal HyperLynx stop working(not responding) and gets closed automatically. It also works...

View Article

Image may be NSFW.
Clik here to view.

How to ignore the Power Net Extraction in an LVS BOX cell

Hi ,     I've a database with some IPs and clock tree network inside. The Power Supply for this one is distributed from TOP to each VDD/VSS Pin of std cells (used for clock tree network) and VDD/VSS...

View Article


Re: ECO Errors from PADS Logic to PADS Layout

I think you'll need to open a service request and have Mentor help you figure this out. 

View Article

Re: How to get a list of open netlines

Hi,Use the Review Hazards (Ctrl+Alt+H) and then the "Online" tab.Now select "Open Netlines". Wim.

View Article


Is it possible to export a Design Capture schematic to VisECAD?

Is it possible to export a Design Capture schematic to a file-format supported by VisECAD? I have a .cce-file of my layout and would like to be able to crossprobe against the schematic. Or do I have to...

View Article

Re: How to get a list of open netlines

Thank Wim

View Article

Re: 3D PCB viewer

Jerry, Thanks for the additional information. I know that the Xpedition 3D option is very powerful, but something worries me.It is an option, where other software, like Altium (costs a 1/3 in...