Re: VX1.2 - Script - CellEditorGRAPHICS - Adding "Property_Text" in BATCH
Many thanks Mike Martin
View Articlecorrect settings for a design with an e.MMC component?
I would like to route an e.mmc-component. In this case, there is the special request that unused pins of the component are used for routing. That means, all unused pins of the component are defined "no...
View ArticleUnable to switch Interactive DRC off/on in ExpeditionPCB using automation
Hello All, In visual basic or visual basic .NET, is there a way to handle interactive DRC status through automation?Intention is to switch DRC off/on through automation, during which some other...
View ArticleDxDesigner - meaning of "Symbol contains uncommited changes"
Do anybody know what the comment "Symbol contains uncommited changes" at a block symbol means?Additionally the block symbol is marked with a red star.
View ArticleCAPITAL LOGIC/DESIGN - WIRE - HOW TO SELECT WIRES WITH CROSS REFERENCE
Hi All, I need to know how to select only wires with cross reference....I printed diagrams with option, "Distributate Splice" unselected, but now I need to select all wires with cross reference...How...
View ArticleRe: Unable to switch Interactive DRC off/on in ExpeditionPCB using automation
You can use transactionStart and transactionEnd (see expedition automation help for more info).It should also make it faster when doing alot of actions and also groups the actions into one undo....
View ArticleRe: correct settings for a design with an e.MMC component?
Hi,I also had this component and some pins are actually RFU (reserved for future use) in the JEDEC spec so those have to be left floating.So for this reason I recommend to do it in the schematic (maybe...
View ArticleRe: Can't start or install PADS 9.5
Joel, I recommend opening a Service Request for this problem. Guy
View Articlecustomize style set
how to customize the style set?how to show the properties of the component in layout near by those components using style set?whether it is done through plugin impoting or it can be done mannually?if...
View ArticleRe: Unable to switch Interactive DRC off/on in ExpeditionPCB using automation
Hello matthias,We are able to control the checkbox that is used to switch the drc off/on, but the issue is with suppressing the windows that comes next.Below is the snapshot that has to be suppressed...
View ArticleRe: customize style set
Hello Dinesh Kumar,Good day! We can show the properties value of the component in many ways depend on the way you want to display using style sets.As an an example this device as a property name:...
View ArticleRe: Unable to switch Interactive DRC off/on in ExpeditionPCB using automation
Hello Bharadwaj,If you put all the actions between the transactionstart and transactionend you don't need to disable it in the editorcontrol.There is also the option to use...
View ArticleRe: correct settings for a design with an e.MMC component?
Hi Matthias,in the meantime, I think also the best way is to define a special symbol with NC-pins and RFU-pins. In this case it will be clearly documented and the drc-violations are avoided.
View ArticleExisiting Project is not visible
In 2015.1 SP1606Step 1.When I search existing project_1 in Capital project, its invisible Step 2. To cross check its real existence ,When I list existing project_1 using List Projects Web service, it...
View ArticleRe: copying circuits in logic and layout
I did it a few years ago with 9.#. I believe the process was something like this: Open 'Sch A' and copy the circuit that you want to copy in Logic to a new page and save it as a new design (Sch B)....
View ArticleIs there any way to easily program your F keys for Xpedition?
F4 is blank and it would be nice to have it set to Toggle Gloss. =)
View ArticleRe: DxDesigner - meaning of "Symbol contains uncommited changes"
This is a new feature in VX.2 when editing local symbols such as block symbols. In prior releases any changes were committed to the schematic as soon as you closed/saved the symbol, now you need to...
View ArticleRe: DxDesigner - meaning of "Symbol contains uncommited changes"
Hi Robert, many thanks for your response. We use VX.1 It seems that this functions is already available at this release. At first I was confused because I tried to use the UPDATE SYMBOL IN DESIGN...
View ArticleNecessity of 2W between Differential pairs ?
Hello All , We have came across a stackup where we are not getting 2W spacing between differential pairs . Trace width for maintaining 100 ohm is 5.5mil and spacing between differential pairs is 7mil ....
View Article